KAN-therm: Scope of application
Main image. Main image. Main image. Main image. Main image.


Scope of application

 

KAN-therm Push System is designed for internal water supply systems (hot and cold tap water) and heating systems, first of all for apartment distributions in a block of flats and for complete installations in single-family houses.

Typical working parameters of a KAN-therm Push installation:

Working parameters PE-RT and PEXCc tubes

Heating systems
(4 and 5 application class to ISO 10508)

Hot and cold water domestic system
(1 and application class to ISO 10508))

Working temperature [°C] 80 60
Max temperature [°C] 90 80
Emergency temperature [°C] 100 95
Working pressure 6 bar 10 bar

 

For custom use please contact our technical advisors.